max

Thursday

Whirlpool duet shows F70 and F71 error code ?

F70 and F71 are two logic board error codes that point at a communication error between the main logic module and the control pad (user interface and CCU), and between the motor control unit and central control (MCU, andd CCU that is main control module).
Repair is difficult, as motor, wiring and voltages from control modules must be tested.

Try first doing a reset, by disconnecting power cord or tripping circuit breaker and leaving power off for five minutes.

If that does not help and errors come back, then the best thing to do is calling the service number listed on the user manual.

Here extensive explanation of error codes and relative troubleshooting:

F70: CENTRAL CONTROL UNIT HEARTBEAT FAILURE
If a Central Control Unit Heartbeat Failure is displayed, no communication is detected from the Central Control Unit to the User Interface.

1. Check for continuity of the User Interface harness.
2. Check wire harness connections to the User Interface and the Central Control Unit.
3. Replace User Interface if drum is rotating.
4. Replace Central Control Unit if drum is not moving

F71: USER INTERFACE HEARTBEAT FAILURE
If a Central Control Unit Heartbeat Failure is displayed, no communication is detected from the User Interface to the Central Control Unit.

1. Check for continuity of the User Interface harness.
2. Check wire harness connections to the User Interface and the Central Control Unit.
3. Replace User Interface if drum is rotating.
4. Replace Central Control Unit if drum is not moving.

To get parts and diagrams try entering the full model number in one of the websites below:

Enter the model number ..