The sensor assembly # 6877A30013M is the most common reason for this type of problem. However, the main PCB # 6871A10142A can also cause this. The thermister needs to be by passed and checked.Disconnect thermister and connect its two wire together and see if that helps, if not then its control board issue.It's very difficult to determine which part has failed in board. I recommend having a technician make this check. I'm listing a site you can access to have a tech come out or for the nearest repair center. Here is a link for the website: Sears Home Services . It's also possible there could be a seal system problem but since it's only running for such a short time, it may not be long enough, to collect any water.

--------